EJX110A Differential Pressure Transmitter (GS 01C25B01-01EN)
01 Output Signal
(Please make one selection)
-D
4 to 20 mA DC with digital communication (BRAIN protocol)
2;
-E
4 to 20 mA DC with digital communication (HART protocol)
3;
-F
Digital communication (FOUNDATION Fieldbus protocol)
4;
-G
Digital communication (PROFIBUS PA protocol)
5;
-J
4 to 20 mA DC with digital communication (HART 5/HART 7 protocol)
6;
2;
2;
02 Measurement Span (Capsule)
(Please make one selection)
F
0.4 to 20 inH2O
1, 2
7;
H
10 to 2,000 inH2O
8;
L
0.4 to 40 inH2O
1, 3
9;
M
2 to 400 inH2O
10;
V
10 to 2,000 psi
11;
3;
3;
03 Wetted Parts Material
(Please make one selection)
A
Cover flange: Hastelloy C-276 equiv. Capsule: Hastelloy C-276(diaphragm and others) Process connector: Hastelloy C-276 equiv. Vent plug: Hastelloy C-276
12;
B
Cover flange: Monel equivalent Capsule: Monel(diaphragm and others) Process connector: Monel equivalent vent plug: Monel
13;
D
Cover flange: Hastelloy C-276 equiv. Capsule: Tantalum(diaphragm and others) Process connector: Hastelloy C-276 equiv. Vent plug: Hastelloy C-276
14;
H
Cover flange: ASTM CF-8M Capsule: Hatelloy C-276(diaphragm and others) Process connector: ASTM CF-8M Vent plug: 316 SST
15;
L
Cover flange: ASTM CF-3M, Capsule: Hastelloy C-276(diaphragm), (F)316L SST(others), Vent plug: 316L SST Process connector: ASTM CF-3M
16;
M
Cover flange: ASTM CF-8M Capsule: Monel (diaphragm and others) Process connector: ASTM CF-8M Vent plug: 316 SST
17;
S
Cover flange: ASTM CF-8M, Capsule: Hastelloy C-276(diaphragm), (F)316L SST(others), Vent plug: 316 SST, Process connector: ASTM CF-8M
8
18;
T
Cover flange: ASTM CF-8M Diaphragm: Tantalum Vent plug: 316 SST Process connector: ASTM CF-8M
19;
W
Cover flange, process connector: Super Duplex SST equiv. Capsule: Hastelloy C-276(diaphragm and others) Vent plug: Super Duplex SST
20;
4;
4;
04 Process Connections
(Please make one selection)
0
Without process connector (RC 1/4 female on cover flange)
21;
1
With Rc1/4 female process connector
22;
2
With Rc1/2 female process connector
23;
3
With 1/4NPT female process connector
24;
4
With 1/2NPT female process connector
25;
5
Without process connector (1/4 NPT female on cover flange)
9
26;
W
Assembled with low volume cover flanges for diaphragm seal units with two M12 x 1.25 female threads, and shipped with two new capsule gaskets
10
27;
5;
5;
05 Bolts and Nuts Material
(Please make one selection)
C
ASTM grade660 stainless steel
28;
G
316L SST
29;
J
ASTM-B7 carbon steel
30;
6;
6;
06 Installation
(Please make one selection)
-7
Vertical impulse piping type, left side high pressure, process connectors downside
31;
-8
Horizontal impulse piping type, right side high pressure
32;
-9
Horizontal impulse piping type, left side high pressure
8
33;
-B
Bottom process connection type, left side high pressure
18
34;
-U
Universal flange
2
35;
7;
7;
07 Amplifier Housing
(Please make one selection)
1
Material: Cast-aluminum alloy
36;
2
Material: ASTM CF-8M
5
37;
3
Material: Cast aluminum alloy with corrosion resistance properties
5
38;
8;
8;
08 Electrical Connection (2 Connectors)
(Please make one selection)
0
G 1/2 female, one electrical connection, without blind plugs
39;
2
1/2 NPT female, two electrical connections, without blind plugs
40;
4
M20 female, two electrical connections without blind plugs
41;
5
G 1/2 female, two electrical connections with a blind plug
6
42;
7
1/2 NPT female, two electrical connections with a blind plug
6
43;
9
M20 female, two electrical connections with a blind plug
6
44;
A
G 1/2 female, two electrical connections with a 316 SST blind plug
45;
C
1/2 NPT female, two electrical connections with a 316 SST blind plug
46;
D
M20 female, two electrical connections with a 316 SST blind plug
47;
9;
9;
09 Integral Indicator
(Please make one selection)
D
Digital indicator
19
48;
E
Digital indicator with a range setting switch
7
49;
N
None
50;
10;
10;
10 Mounting Bracket
(Please make one selection)
B
304 SST 2-inch pipe mounting(flat type)
51;
D
304 SST or SCS13A 2-inch pipe mounting(L type)
52;
J
316 SST 2-inch pipe mounting(flat type)
53;
K
316 SST or SCS14A 2-inch pipe mounting(L type)
54;
M
316 SST or SCS14A 2-inch pipe mounting (for bottom process connection)
15
55;
N
None
56;
P
Position adjustable bracket for vertical piping installation, SUS316, 2-inch pipe mounting(L type)
57;
11;
11;
001 Optional Features
/CF1
CSA Explosionproof Approval
(For Output Code -D, -E, -J, -F, or -G)
4
58;
/CS1
CSA Intrinsically safe Approval
(For Output Code -D, -E, or -J)
11
59;
/CS15
CSA Intrinsically safe approval
(For Output Signal code -F)
11
60;
/CU1
Combined /CF1 and /CS1
(For Output Code -D, -E, or -J)
11
61;
/FF1
FM Explosionproof Approval (For Output Code -D, -E, -J, -F, or -G)
4
62;
/FS1
FM Intrinsically Safe Approval
(For Output Code -D, -E, or -J)
11
63;
/FS15
FM Intrinsically Safe and Non-incendive Approval
(For Output Code -F)
11
64;
/FU1
Combined /FF1 and /FS1
(For Output Code -D, -E, or -J)
11
65;
/KF22
ATEX Flameproof Approval (For Output Code -D, -E, -J, -F, or -G)
4
66;
/KN26
ATEX Type n Approval
(For Output Code -F or -G)
11
67;
/KS21
ATEX Intrinsically safe Approval
(For Output Code -D, -E, or -J)
11
68;
/KS26
ATEX Intrinsically safe Approval
(For Output Code -F or -G)
11
69;
/KU22
Combined /KF22, /KS21, and Type n
(For Output Code -D, -E, or -J)
11
70;
/NF21
NEPSI Flameproof and Dust Ignition Proof approval (Output Signal code -D, -E, or -J)
4
71;
/NS21
NEPSI Intrinsically safe Approval (For Output Signal code -D, -E, or -J)
11
72;
/NS25
NEPSI Intrinsic safety Approval (Output Signal code -F)
11
73;
/PF22
KOSHA Flameproof Approval (For Output Signal code -D or -J)
4
74;
/PS21
KOSHA Intrinsically safe Approval (For Output Signal code -D or -J)
11
75;
/SF22
IECEx flameproof approval
(For Output Signal code -D, -J, -F, -G or -Q)
4
76;
/SS26
IECEx Intrinsically safe Approval (Output Signal code -F and -G)
11
77;
/SU22
IECEx Intrinsically safe and flameproof (For Output Signal code -D or -J)
11
78;
/UF1
INMETRO Flameproof Approval (For Output Signal code -D, -E, or -J)
4
79;
/US1
INMETRO Intrinsically safe Approval (For Output Signal code -D, -E, or -
J)
11
80;
/V1U1
Combination Approval (/KU22, /FU1, and /CU1)
(For Output Signal code -D, -E, or -J)
11
81;
12;
12;
003 Optional Features
/D1
P calibration (psi unit)
13
82;
/D3
bar calibration (bar unit)
13
83;
/D4
M calibration (kgf/cm2 unit)
13
84;
13;
13;
004 Optional Features
/P1
Color change, amplifier cover only Munsell code ; N1.5, black
21
85;
/P2
Color change, amplifier cover only Munsell code ; 7.5BG4/1.5, jade green
21
86;
/P7
Color change, amplifier cover only Metallic silver
21
87;
/PR
Color change, amplifier and terminal covers Munsell code ; 7.5 R4/14, Red
21
88;
14;
14;
005 Optional Features
/X2
High anti-corrosion coating
20
89;
15;
15;
006 Optional Features
/A
Lightning protector
90;
16;
16;
007 Optional Features
/K1
Degrease cleansing treatment
12
91;
/K2
Degrease cleansing treatment and with fluorinated oil filled capsule
12
92;
/K3
Fluorinated oil filled capsule
93;
/K41
Degrease cleansing treatment and implementation certificate
12
94;
/K42
Degrease cleansing treatment with fluorinated oil filled capsule, and implementation certificate
12
95;
/K45
Degrease cleansing and dehydrating treatment, and implementation certificate
12
96;
/K46
Degrease cleansing and dehydrating treatment with fluorinated oil filled capsule, and implementation certificate
12
97;
/K5
Degrease cleansing and dehydrating treatment
12
98;
/K6
Degrease cleansing and dehydrating treatment with fluorinated oil filled capsule
12
99;
17;
17;
008 Optional Features
/U1
Long vent
100;
18;
18;
009 Optional Features
/C1
Output status at CPU failure and hardware error is -5%, 3.2 mA or less.
101;
/C2
Output signal limits: 3.8 mA to 20.5 mA Output status at CPU failure and hardware error is -5%, 3.2 mA or less.
102;
/C3
Output signal limits: 3.8 mA to 20.5 mA Output status at CPU failure and hardware error is 110%, 21.6 mA or more.
103;
19;
19;
010 Optional Features
/CA
Data Configuration for HART communication type (Software damping,Descriptor and Message)
104;
/CB
Data Configuration for BRAIN communication type (Software damping)
105;
/CC
Data Configuration for FOUNDATION Fieldbus communication type (Software damping)
106;
/CD
Data configuration for PROFIBUS PA communication type (Software damping)
107;
/CJ
Data configuration(for HART): Disabling external zero adjustment, Software damping, Descriptor and Message
108;
/CK
Data configuration(for BRAIN): Disables external zero adjustment, Software damping
109;
20;
20;
011 Optional Features
/M01
Material certificate:cover flange
22
110;
/M11
Material certificate:cover flange, process connector
22
111;
/MA1
Material certificate: Cover flange, diaphragm, capsule body
112;
/MC1
Material certificate: Cover flange, process connector, diaphragm, capsule body
113;
/MG1
Material certificate for wetted parts including cover flange, bolt and nut for cover flange, diaphragm, capsule body, vent and drain plug, vent screw, capsule gasket
114;
/MH1
Material certificate for wetted parts including cover flange, process connector, bolt and nut for cover flange, bolt for process connector, diaphragm, capsule body, vent and drain plug, vent screw, capsule gasket
115;
21;
21;
012 Optional Features
/T12
Pressure test/leak test certificate Test pressure:16 MPa(2300 psi)
22
116;
/T13
Pressure test/leak test certificate Test pressure:25 MPa(3600 psi)
22
117;
22;
22;
013 Optional Features
/N1
Right side high pressure. Without drain and vent plugs.
118;
/N2
Right side high pressure. IEC61518 pro- cess connection with female threads on cover flanges, with blind kidney flanges on back. Without drain and vent plugs.
119;
/N3
Right side high pressure. /N1,/N2 and material certificate for cover flange, diaphragm, capsule body and blind kidney flange.
120;
23;
23;
014 Optional Features
/N4
Stainless steel tag plate wired onto the transmitter
28
121;
24;
24;
016 Optional Features
/A1
Gold-plated diaphragm
26
122;
/A2
Gold-plated diaphragm (10 micro meter)
23
123;
25;
25;
017 Optional Features
/AL
Status output
124;
26;
26;
019 Optional Features
/HAC
High accuracy type Reference accuracy: +/-0.025% of span (Refer to GS for details.)
24
125;
27;
27;
021 Optional Features
/EE
Software Download
126;
28;
28;
023 Optional Features
/PE3
European Pressure Equipment Directive Category III
17
127;
29;
29;
026 Optional Features
/DG1
Multi-sensing process monitoring function: Impulse Line Blockage Detection and Heat trace monitoring
128;
/DG6
Multi-sensing process monitoring function: Impulse Line Blockage Detection and Heat trace monitoring
129;
30;
30;
027 Optional Features
/HC
316 SST exterior parts
16
130;
31;
31;
028 Optional Features
/GS
Gold-plated capsule gasket Without drain and vent plugs
25
131;
32;
32;
035 Optional Features
/HD
High damping capsule
132;
33;
33;
036 Optional Features
/WCA
American Bureau of Shipping (ABS) Type Approval (For Output Signal
code -D or -J)
133;
/WCB
Bureau Veritas Type Approval
134;
/WCD
Det Norske Veritas (DNV) Type Approval (For Output Signal code -D or -
J)
135;
/WCL
Lloyd's Register of Shipping Type Approval (For Output Signal code -D
or -J)
136;
/WCN
NK(Nippon Kaiji Kyokai) Type approval
137;
34;
34;
039 Optional Features
/YP
Parameter List
138;
35;
35;
043 Optional Features
/SLT
Low temperature expansion of functional safety ambient temperature
139;
36;
36;
046 Optional Features
/L4
Calibration certificate: Introduction and Yokogawa traceability control system
140;
/L5
Calibration certificate: Introduction, Yokogawa traceability control system, and primary standards list
141;
/L6
Calibration certificate: Introduction, Yokogawa traceability control system, primary standards list, and calibration equipments list
142;
/L9
Calibration certificate: Introduction, Yokogawa traceability control system, primary standards list, calibration equipments list and their test cert.
143;
37;
37;
050 Optional Features
/BS
Bug screen
29
144;
38;
38;
051 Optional Features
/PP
An additional blind plug
28
145;
39;
39;