RCNS34H Spare Sensor RM TI Supreme, 5t/h, HC
01 process con. size and type
(Please make one selection)
1
-25BA1
1" ASME flange class 150, process connection dimension and facing according ASME B16.5
2;
-25BA2
1" ASME flange class 300, process connection dimension and facing according ASME B16.5
3;
-25BA4
1" ASME flange class 600, process connection dimension and facing according ASME B16.5
4;
-40BA1
1 1/2" ASME flange class 150, process connection dimension and facing according ASME B16.5
5;
-40BA2
1 1/2" ASME flange class 300, process connection dimension and facing according ASME B16.5
6;
-40BA4
1 1/2" ASME flange class 600, process connection dimension and facing according ASME B16.5
7;
-50BA1
2" ASME flange class 150, process connection dimension and facing according ASME B16.5
8;
-50BA2
2" ASME flange class 300, process connection dimension and facing according ASME B16.5
9;
-50BA4
2" ASME flange class 600, process connection dimension and facing according ASME B16.5
10;
2;
2;
02 Sensor housing material
(Please make one selection)
1
0
Sensor housing mat SUS 304 Sensor housing material SUS 304 (1.4301)
11;
1
Sensor hous. mat 316L/1.4404 Sensor housing material SUS 316L(1.4404)
12;
3;
3;
03 Process fluid temp. range
(Please make one selection)
1
-0
standard process fluid temperature range remote: -70 to 150°C (-56,7 to 302 °F)
13;
-2
mid temperature process fluid temperature range remote: -70 to 230°C (-56,7 to 446 °F)
2
14;
-3
high temperature process fluid temperature range remote: 0 to 350°C (32 to 662 °F)
2
15;
4;
4;
04 mass flow and density acc.
(Please make one selection)
1
50
G: 0,5% m flow Gas: 0,5% mass flow accuracy
3,4
16;
C2
L: 0,1% m flow+0.5 kg/m³ Liquid: 0,1% mass flow accuracy and 0.5 kg/m³ density accuracy
3
17;
C6
L: 0,1% m flow+3 kg/m³ liquid: 0,1% mass flow accuracy and 3 kg/m³ density accuracy
3
18;
5;
5;
05 Design and housing
(Please make one selection)
1
A
R:AL UP+SS std-neck Remote: low copper aluminium housing, urethane-cured polyester powder coating SS terminal housing standard neck
19;
B
R:AL UP+SS long-neck Remote: low copper aluminium housing, urethane-cured polyester powder coating SS terminal housing long neck
20;
E
R:AL corr paint+ std-neck Remote: low copper aluminium housing, corrosion protection coating SS terminal housing standard neck
21;
F
R:AL corr paint+SS long-neck Remote: low copper aluminium housing, corrosion protection coating SS terminal housing long neck
22;
J
R:SS trans+SS std-neck Remote: stainless steel housing stainless steel terminal housing standard neck
5
23;
K
R:SS trans+SS long-neck Remote: stainless steel housing stainless steel terminal housing long neck
24;
6;
6;
06 Ex approval
(Please make one selection)
1
-FF11
FM XP tra+IS sen ABCDEFG FM approval for USA and Canada, explosionproof transmitter and intrinsic safe sensor (GP ABCDEFG)
25;
-FF12
FM XP tra+IS sen CDEFG FM approval for USA and Canada, explosionproof transmitter and intrinsic safe sensor (GP CDEFG)
26;
-NN00
Non Ex proof Non Ex proof
27;
7;
7;
07 Cable entries
1
-2
ANSI 1/2 in. NPT
28;
8;
8;
08 Communication type and I/O
1
-NN
all com. type + I/Os apply Spare sensor without transmitter, all communication types and I/Os apply
29;
9;
9;
09 display
1
N
No display applied Spare sensor without transmitter, no display applied
30;
10;
10;
002 Add. namplate information
1
/BG
Tag number on nameplate Customer-specific tag number on nameplate
31;
11;
11;
005 Country-specific appl.
1
/CS
CRN Canadian Registration Number CRN
6
32;
12;
12;
007 Rupture disc
1
/RD
rupture disk rupture disk
33;
13;
13;
009 Accord. w. terms of order
1
/P2
2.1 certificate EN 10204 Declaration of compliance with the order 2.1 acc. EN 10204
34;
/P3
3.1 certificate EN 10204 Inspection certificate 3.1 acc. EN 10204 (QIC)
7
35;
14;
14;
010 material certificates
1
/P6
material certificate acc. to EN 10204: 2004 -3.1 incl. IGC conform to NACE MR0175, MR0103
7
36;
15;
15;
012 Pressure testing
1
/P8
Pressure test certificate Pressure test certificate
8
37;
16;
16;
013 Surface oil & grease free
1
/H1
Degreasing wetted surfaces Degreasing of wetted surfaces acc. ASTM G93/G93M-19, level C, test report
38;
17;
17;
014 welding certificate
1
/WP
incl.: WPS, WPQR, WQC WPS according DIN EN ISO 15609-1, WPQR according DIN EN ISO 15614-1, WQC according DIN EN 287-1 and ISO6906-4
15
39;
/WPA
Weld. proced. acc ASME IX Welding procedures and certificate welding according ASME IX
9,10
40;
18;
18;
016 ASME B31.3 compliance
1
/P15
ASME B31.3 NORM FLU. SER ASME B31.3 compliance NORMAL FLUID SERVICE
10,11
41;
19;
19;
018 PMI of wetted parts
1
/PM
PMI test PMI test for pressure containing parts, including certificate
12
42;
20;
20;
019 Dye penetr. test weld seam
1
/PT
Dye pen test flange weld Dye penetrant test of flange welding acc. DIN EN ISO 3452-1 including test report
15
43;
/PTA
Dye pen. test acc ASME V Dye penetrant test of flange welding acc. ASME V including test report
9,10
44;
21;
21;
027 Insulation & heat tracing
1
/T10
Insulation Insulation
13,14
45;
/T21
/T10+heat. ASME1/2in. 150 Insulation and heat tracing with ASME 1/2 in. class 150 connection raised face
13,14
46;
/T31
/T21+ventilation Insulation, heat tracing and ventilation with ASME 1/2 in. class 150 connection raised face
13,14
47;
22;
22;