RCES38S Qnom= 32 t/h (1200 lb/min)
01 Process Connection
(Please make one selection)
-40BA1
1 1/2" ASME flange class 150, process connection dimension and facing according ASME B16.5
1
2;
-40BA2
1 1/2" ASME flange class 300, process connection dimension and facing according ASME B16.5
1
3;
-40BA4
1 1/2" ASME flange class 600, process connection dimension and facing according ASME B16.5
1
4;
-40CA4
1 1/2" ASME flange class 600, process connection dimension and facing according ASME B16.5, ring joint
1
5;
-50BA1
2" ASME flange class 150, process connection dimension and facing according ASME B16.5
1
6;
-50BA2
2" ASME flange class 300, process connection dimension and facing according ASME B16.5
1
7;
-50BA4
2" ASME flange class 600, process connection dimension and facing according ASME B16.5
1
8;
-50CA4
2" ASME flange class 600, process connection dimension and facing according ASME B16.5, ring joint
1
9;
-50HS8
HS8 clamp connection, process connection dimension and facing according DIN 32676 series C
1
10;
-80BA1
3" ASME flange class 150, process connection dimension and facing according ASME B16.5
1
11;
-80BA2
3" ASME flange class 300, process connection dimension and facing according ASME B16.5
1
12;
-80BA4
3" ASME flange class 600, process connection dimension and facing according ASME B16.5
1
13;
-80CA4
3" ASME flange class 600, process connection dimension and facing according ASME B16.5, ring joint
1
14;
-80HS8
HS8 clamp connection, process connection dimension and facing according DIN 32676 series C
1
15;
2;
2;
02 Sensor housing material
(Please make one selection)
0
sensor housing material SUS 304 (1.4301)
16;
1
sensor housing material SUS 316L(1.4404)
17;
3;
3;
03 Medium temperature range
(Please make one selection)
-0
standard process fluid temperature range integral: -50 to 150°C (-58 to 302 °F) remote: -70 to 150°C (-56,7 to 302 °F)
18;
-1
Low Temperature process fluid temperature range remote: -196 to 150°C (-320,8 to 302 °F)
19;
-2
mid temperature process fluid temperature range remote: -70 to 230°C (-56,7 to 446 °F)
2
20;
-3
high temperature process fluid temperature range remote: 0 to 350°C (32 to 662 °F)
2
21;
4;
4;
04 Mass flow and density accuracy
(Please make one selection)
70
G: 0,75% m flow gas: 0,75% mass flow accuracy
22;
D7
L: 0,15% m flow+4 kg/m³ liquid: 0,15% mass flow accuracy and 4 kg/m³ density accuracy
23;
E7
L: 0,2% m flow+4 kg/m³ liquid: 0,2% mass flow accuracy and 4 kg/m³ density accuracy
24;
5;
5;
05 Design and housing
(Please make one selection)
0
I:AL housing UP paint integral: low copper aluminium housing urethane-cured polyester powder coating
25;
2
I:AL housing corrosion paint integral: low copper aluminium housing corrosion protection coating
4
26;
A
R:AL UP+SS std-neck remote: low copper aluminium housing urethane-cured polyester powder coating SS terminal housing standard neck
4
27;
B
R:AL UP+SS long-neck remote: low copper aluminium housing urethane-cured polyester powder coating SS terminal housing long neck
28;
E
R:AL corr paint+ std-neck remote: low copper aluminium housing corrosion protection coating SS terminal housing standard neck
29;
F
R:AL corr paint+SS long-neck remote: low copper aluminium housing corrosion protection coating SS terminal housing long neck
30;
J
R:SS trans+SS std-neck remote: stainless steel housing stainless steel terminal housing standard neck
10
31;
K
R:SS trans+SS long-neck remote: stainless steel housing stainless steel terminal housing long neck
11
32;
6;
6;
06 Ex approval
(Please make one selection)
-FF11
FM XP tra+IS sen ABCDEFG FM approval for USA and Canada explosionproof transmitter and intrinsic safe sensor (GP ABCDEFG)
33;
-FF12
FM XP tra+IS sen CDEFG FM approval for USA and Canada explosionproof transmitter and intrinsic safe sensor (GP CDEFG)
34;
-NN00
non Ex proof
5
35;
7;
7;
07 Cable entries
-2
ANSI 1/2 in. NPT
36;
8;
8;
08 Communication type and I/O
(Please make one selection)
-JA
IOa, PLp 1 active current output HART, 1 passive pulse output or status output
6
37;
-JB
IOa, PLp, PLp, IOa 2 active current output HART 2 passive pulse output or status output
6
38;
-JC
IOa, PLp, DI, IOa 2 active current output HART 1 passive pulse output or status output 1 voltage-free digital input
6
39;
-JD
IOa, PLp,STp, PLp 1 active current output HART 2 passive pulse output or status output 1 passive status output
6
40;
-JE
IOa, PLp, DI, PLp 1 active current output HART 2 passive pulse output or status output 1 voltage-free digital input
6
41;
-JF
IOa, PLp, DI, PLa pull-up 1 active current out HART, 1 passive pulse or statusout,1active pull-up pulse or statusout,1voltage-free digital input
6
42;
-JG
IOa, PLp, DI, PLa 1 active current out HART, 1 passive pulse or status out, 1 active pulse or status out, 1 voltage-free digital input
6
43;
-JP
IOp, PLp, IOp 1 passive current output HART, 1 passive pulse output or status output, 1 passive current output,
6,7
44;
-JQ
IOp, PLp, IOp, PLp 1 passive current output HART, 2 passive pulse output or status output, 1 passive current output
6,7
45;
-JR
IOp, NamPLp, IOp, 1 passive current output HART, 1 passive Namur pulse or status output, 1 passive current output
6,7
46;
-JS
IOp, NamPLp, IOp, NamPLp 1 passive current output HART, 2 passive Namur pulse or status output, 1 passive current output
6,7
47;
-M0
MB, PLp 1 passive pulse output or status output, Modbus
12
48;
-M3
MB, PLp, PLp 2 passive pulse output or status output, Modbus
12
49;
-M4
MB, PLa, PLp 1 active pulse output or status output, 1 passive pulse output or status output, Modbus
12
50;
-M5
MB, PLa pull-up, PLp 1 active pulse ouput or status output with internal pull-up resistor, 1 passive pulse out or status out,Modbus
12
51;
-M6
MB, IOa, PLp 1 active current output, 1 passive pulse output or status output, Modbus
12
52;
9;
9;
09 Display
(Please make one selection)
0
no display
53;
1
with display
54;
10;
10;
002 Add. namplate information
/BG
Tag number on nameplate Customer-specific tag number on nameplate
55;
11;
11;
003 Pre-setting custom. Param.
/PS
Presetting sel. parameters Presetting of selected parameters based on customer data
15
56;
12;
12;
005 Country-specific appl.
/CS
CRN Canadian Registration Number CRN
57;
13;
13;
007 Rupture disc
/RD
rupture disk rupture disk
58;
14;
14;
008 Customer-specific calibr.
/K2
5 pt calibr+factory cert Customized 5 point mass-/volume-flow calibration using water with factory certificate
59;
/K5
10 pt calibr+Dakks cert Customized 10 point mass-/volume-flow calibration using water with DAkkS certificate
60;
15;
15;
009 Certificate of Compliance
/P2
2.1 certificate EN 10204 Declaration of compliance with the order 2.1 acc. EN 10204
61;
/P3
3.1 certificate EN 10204 Inspection certificate 3.1 acc. EN 10204 (QIC)
62;
16;
16;
010 material certificates
/P6
material certificate acc. to EN 10204: 2004 -3.1 incl. IGC conform to NACE MR0175, MR0103
63;
17;
17;
011 Sanitary options
/SA
3-A product conformity Surface Roughness wetted parts Ra<=0.8µm test report, 3-A certificate and marking
22,23,24
64;
/SF1
Surface roughn. Ra<=0.8µm Surface Roughness wetted parts Ra<=0.8µm
22,23
65;
/SF2
Test rep. surface roughn. Surface Roughness wetted parts Ra<=0.8µm test report,
22,23
66;
18;
18;
012 Pressure testing
/P8
Pressure test certificate Pressure test certificate
67;
19;
19;
013 Surface oil & grease free
/H1
Degreasing wetted surfaces Degreasing of wetted surfaces acc. ASTM G93/G93M-19, level C, test report
68;
20;
20;
014 welding certificate
/WP
incl.: WPS, WPQR, WQC WPS according DIN EN ISO 15609-1 WPQR according DIN EN ISO 15614-1 WQC according DIN EN 287-1 and ISO6906-4
18
69;
/WPA
Weld. proced. acc ASME IX Welding procedures and certificate welding according ASME IX
16
70;
21;
21;
015 calibration certificate
/L2
calibration certificate with working standards
71;
/L3
calibration certificate with primary standards
72;
/L4
calibration certificate including measuring instruments control system
73;
22;
22;
016 ASME B31.3 compliance
/P15
ASME B31.3 NORM FLU. SER ASME B31.3 compliance NORMAL FLUID SERVICE
16
74;
23;
23;
017 X-ray insp. flg. weld seam
/RT
X-ray test flange weld X-ray examination of flange welding acc. DIN EN ISO 17636-1/B, AD2000 HP 5/3 DIN EN ISO 5817/C, including certificate
18
75;
/RTA
X-ray test acc. ASME V Dye penetrant test of flange welding acc. ASME V including test report
16
76;
24;
24;
018 PMI of wetted parts
/PM
PMI test PMI test for pressure containing parts, including certificate
77;
25;
25;
019 Dye penetr. test weld seam
/PT
Dye pen test flange weld Dye penetrant test of flange welding acc. DIN EN ISO 3452-1 including test report
18
78;
/PTA
Dye pen. test acc ASME V Dye penetrant test of flange welding acc. ASME V including test report
16
79;
26;
26;
020 combined certificate
/P20
comb /PTA+/WPA+/RTA Dye Penetrant test for flange acc ASME V welding procedure for flange acc ASME IX X-ray test according ASME V
17
80;
/P21
comb /P10+/P20 Quality Inspection Cert.(QIC), cert. of marking transfer, pressure test cert. , ASME cert. Package
19,20
81;
/P22
comb /P11+/P20 Quality Insp. Cert.(QIC), cert. of marking transfer, ASME cert. Package, PMI test of pressure containing parts
20,21
82;
27;
27;
021 Tube health check
/TC
Tube health check Tube health check
83;
28;
28;
024 Transmitter rotated 180°
/RB
180° rotatable term box 180 degrees rotated terminal box
84;
29;
29;
027 Insulation & heat tracing
/T10
insulation
2
85;
/T21
/T10+heat. ASME1/2in. 150 Insulation and heat tracing with ASME 1/2 in. class 150 connection raised face
2
86;
/T31
/T21+ventilation Insulation, heat tracing and ventilation with ASME 1/2 in. class 150 connection raised face
2
87;
30;
30;
034 Connect. cable type + len.
/L000
No std connecting cab No standard connecting cable separate order for standard sensor cable
8
88;
/L005
5m (16,4 ft) std cab 5 meter (16,4 ft) remote sensor cable terminated non Ex black / Ex blue
8
89;
/L010
10m (32,8 ft) std cab 10 meter (32,8 ft) remote sensor cable terminated non Ex black / Ex blue
8
90;
/L015
15m (49,2 ft) std cab 15 meter (49,2 ft) remote sensor cable terminated non Ex black / Ex blue
8
91;
/L020
20m (65,6 ft) std cab 20 meter (65,6 ft) remote sensor cable terminated non Ex black / Ex blue
8
92;
/L030
30m (98,4 ft) std cab 30 meter (98,4 ft) remote sensor cable terminated non Ex black / Ex blue
8
93;
31;
31;
036 Customized install. length
/CL
Customer install. length Customer-specific installation length
25,26,27,31
94;
/NL
NAMUR install. length NAMUR installation length acc. NE132
25,26,27,31
95;
32;
32;
040 Steel arm. connect. cable
/LAC
Steel armored cable Steel armored version of standard connecting cable
96;
33;
33;