RCEN15K Qnom = 0.37 t/h (14 lb/min)
01 Process Connection
(Please make one selection)
-06TT9
¼" NPT, female thread
1
2;
-08TT9
3/8" NPT, internal thread
1
3;
-15BA1
1/2" ASME flange class 150, process connection dimension and facing according ASME B16.5
1
4;
-15BA2
1/2" ASME flange class 300, process connection dimension and facing according ASME B16.5
1
5;
-15BA4
1/2" ASME flange class 600, process connection dimension and facing according ASME B16.5
1
6;
-15BA5
1/2" ASME flange class 900, process connection dimension and facing according ASME B16.5
1
7;
-15BA6
1/2" ASME flange class 1500, process connection dimension and facing according ASME B16.5
1
8;
-15CA4
1/2" ASME flange class 600, process connection dimension and facing according ASME B16.5, ring joint
1
9;
-15CA5
1/2" ASME flange class 900, process connection dimension and facing according ASME B16.5, ring joint
1
10;
-15CA6
1/2"ASME flange class 1500, process connection dimension and facing according ASME B16.5, ring joint
1
11;
-15TT9
1/2" NPT, internal thread
1
12;
-20TT9
3/4" NPT, internal thread
1
13;
-25BA1
1" ASME flange class 150, process connection dimension and facing according ASME B16.5
1
14;
-25BA2
1" ASME flange class 300, process connection dimension and facing according ASME B16.5
1
15;
-25BA4
1" ASME flange class 600, process connection dimension and facing according ASME B16.5
1
16;
-25BA5
1" ASME flange class 900, process connection dimension and facing according ASME B16.5
1
17;
-25BA6
1" ASME flange class 1500, process connection dimension and facing according ASME B16.5
1
18;
-25CA4
1" ASME flange class 600, process connection dimension and facing according ASME B16.5, ring joint
1
19;
-25CA5
1" ASME flange class 900, process connection dimension and facing according ASME B16.5, ring joint
1
20;
-25CA6
1" ASME flange class 1500, process connection dimension and facing according ASME B16.5, ring joint
1
21;
-40BA1
1 1/2" ASME flange class 150, process connection dimension and facing according ASME B16.5
1
22;
-40BA2
1 1/2" ASME flange class 300, process connection dimension and facing according ASME B16.5
1
23;
-40BA4
1 1/2" ASME flange class 600, process connection dimension and facing according ASME B16.5
1
24;
-40BA5
1 1/2"ASME flange class 900, process connection dimension and facing according ASME B16.5
1
25;
-40BA6
1 1/2"ASME flange class 1500, process connection dimension and facing according ASME B16.5
1
26;
-40CA4
1 1/2" ASME flange class 600, process connection dimension and facing according ASME B16.5, ring joint
1
27;
-40CA5
1 1/2"ASME flange class 900, process connection dimension and facing according ASME B16.5, ring joint
1
28;
-40CA6
1 1/2"ASME flange class 1500, process connection dimension and facing according ASME B16.5, ring joint
1
29;
2;
2;
02 Sensor housing material
(Please make one selection)
0
sensor housing material SUS 304 (1.4301)
30;
1
sensor housing material SUS 316L(1.4404)
31;
3;
3;
03 Medium temperature range
(Please make one selection)
-0
standard process fluid temperature range remote: -50 to 150°C (-58 to 302 °F)
32;
-2
mid temperature process fluid temperature range remote: -50 to 260°C (-58 to 500 °F)
2
33;
4;
4;
04 Mass flow and density accuracy
(Please make one selection)
70
G: 0,75% m flow gas: 0,75% mass flow accuracy
34;
E7
L: 0,2% m flow+4 kg/m³ liquid: 0,2% mass flow accuracy and 4 kg/m³ density accuracy
35;
5;
5;
05 Design and housing
(Please make one selection)
A
R:AL UP+SS std-neck remote: low copper aluminium housing urethane-cured polyester powder coating SS terminal housing standard neck
3,4
36;
B
R:AL UP+SS long-neck remote: low copper aluminium housing urethane-cured polyester powder coating SS terminal housing long neck
37;
E
R:AL corr paint+ std-neck remote: low copper aluminium housing corrosion protection coating SS terminal housing standard neck
3,4
38;
F
R:AL corr paint+SS long-neck remote: low copper aluminium housing corrosion protection coating SS terminal housing long neck
39;
J
R:SS trans+SS std-neck remote: stainless steel housing stainless steel terminal housing standard neck
3
40;
K
R:SS trans+SS long-neck remote: stainless steel housing stainless steel terminal housing long neck
41;
6;
6;
06 Ex approval
(Please make one selection)
-FF11
FM XP tra+IS sen ABCDEFG FM approval for USA and Canada explosionproof transmitter and intrinsic safe sensor (GP ABCDEFG)
42;
-FF12
FM XP tra+IS sen CDEFG FM approval for USA and Canada explosionproof transmitter and intrinsic safe sensor (GP CDEFG)
43;
-NN00
non Ex proof
5
44;
7;
7;
07 Cable entries
-2
ANSI 1/2 in. NPT
45;
8;
8;
08 Communication type and I/O
(Please make one selection)
-JA
IOa, PLp 1 active current output HART, 1 passive pulse output or status output
6
46;
-JB
IOa, PLp, PLp, IOa 2 active current output HART 2 passive pulse output or status output
6
47;
-JC
IOa, PLp, DI, IOa 2 active current output HART 1 passive pulse output or status output 1 voltage-free digital input
6
48;
-JD
IOa, PLp,STp, PLp 1 active current output HART 2 passive pulse output or status output 1 passive status output
6
49;
-JE
IOa, PLp, DI, PLp 1 active current output HART 2 passive pulse output or status output 1 voltage-free digital input
6
50;
-JF
IOa, PLp, DI, PLa pull-up 1 active current out HART, 1 passive pulse or statusout,1active pull-up pulse or statusout,1voltage-free digital input
6
51;
-JG
IOa, PLp, DI, PLa 1 active current out HART, 1 passive pulse or status out, 1 active pulse or status out, 1 voltage-free digital input
6
52;
-JP
IOp, PLp, IOp 1 passive current output HART, 1 passive pulse output or status output, 1 passive current output,
6,7
53;
-JQ
IOp, PLp, IOp, PLp 1 passive current output HART, 2 passive pulse output or status output, 1 passive current output
6,7
54;
-JR
IOp, NamPLp, IOp, 1 passive current output HART, 1 passive Namur pulse or status output, 1 passive current output
6,7
55;
-JS
IOp, NamPLp, IOp, NamPLp 1 passive current output HART, 2 passive Namur pulse or status output, 1 passive current output
6,7
56;
-M0
MB, PLp 1 passive pulse output or status output, Modbus
8
57;
-M3
MB, PLp, PLp 2 passive pulse output or status output, Modbus
8
58;
-M4
MB, PLa, PLp 1 active pulse output or status output, 1 passive pulse output or status output, Modbus
8
59;
-M5
MB, PLa pull-up, PLp 1 active pulse ouput or status output with internal pull-up resistor, 1 passive pulse out or status out,Modbus
8
60;
-M6
MB, IOa, PLp 1 active current output, 1 passive pulse output or status output, Modbus
8
61;
9;
9;
09 Display
1
with display
62;
10;
10;
002 Add. namplate information
/BG
Tag number on nameplate Customer-specific tag number on nameplate
63;
11;
11;
003 Pre-setting custom. Param.
/PS
Presetting sel. parameters Presetting of selected parameters based on customer data
14
64;
12;
12;
008 Customer-specific calibr.
/K2
5 pt calibr+factory cert Customized 5 point mass-/volume-flow calibration using water with factory certificate
65;
/K5
10 pt calibr+Dakks cert Customized 10 point mass-/volume-flow calibration using water with DAkkS certificate
66;
13;
13;
009 Certificate of Compliance
/P2
2.1 certificate EN 10204 Declaration of compliance with the order 2.1 acc. EN 10204
67;
/P3
3.1 certificate EN 10204 Inspection certificate 3.1 acc. EN 10204 (QIC)
68;
14;
14;
010 material certificates
/P6
material certificate acc. to EN 10204: 2004 -3.1 incl. IGC conform to NACE MR0175, MR0103
69;
15;
15;
012 Pressure testing
/P8
Pressure test certificate Pressure test certificate
70;
16;
16;
013 Surface oil & grease free
/H1
Degreasing wetted surfaces Degreasing of wetted surfaces acc. ASTM G93/G93M-19, level C, test report
71;
17;
17;
014 welding certificate
/WP
incl.: WPS, WPQR, WQC WPS according DIN EN ISO 15609-1 WPQR according DIN EN ISO 15614-1 WQC according DIN EN 287-1 and ISO6906-4
15
72;
/WPA
Weld. proced. acc ASME IX Welding procedures and certificate welding according ASME IX
13
73;
18;
18;
015 calibration certificate
/L2
calibration certificate with working standards
74;
/L3
calibration certificate with primary standards
75;
/L4
calibration certificate including measuring instruments control system
76;
19;
19;
017 X-ray insp. flg. weld seam
/RT
X-ray test flange weld X-ray examination of flange welding acc. DIN EN ISO 17636-1/B, AD2000 HP 5/3 DIN EN ISO 5817/C, including certificate
15
77;
/RTA
X-ray test acc. ASME V Dye penetrant test of flange welding acc. ASME V including test report
13
78;
20;
20;
018 PMI of wetted parts
/PM
PMI test PMI test for pressure containing parts, including certificate
79;
21;
21;
019 Dye penetr. test weld seam
/PT
Dye pen test flange weld Dye penetrant test of flange welding acc. DIN EN ISO 3452-1 including test report
15
80;
/PTA
Dye pen. test acc ASME V Dye penetrant test of flange welding acc. ASME V including test report
13
81;
22;
22;
020 combined certificate
/P20
comb /PTA+/WPA+/RTA Dye Penetrant test for flange acc ASME V welding procedure for flange acc ASME IX X-ray test according ASME V
12
82;
/P21
comb /P10+/P20 Quality Inspection Cert.(QIC), cert. of marking transfer, pressure test cert. , ASME cert. Package
16, 17
83;
/P22
comb /P11+/P20 Quality Insp. Cert.(QIC), cert. of marking transfer, ASME cert. Package, PMI test of pressure containing parts
17, 18
84;
23;
23;
021 Tube health check
/TC
Tube health check Tube health check
85;
24;
24;
027 Insulation & heat tracing
/T10
insulation
2
86;
/T21
/T10+heat. ASME1/2in. 150 Insulation and heat tracing with ASME 1/2 in. class 150 connection raised face
2
87;
/T22
/T10+heat. ASME1/2in. 300 Insulation and heat tracing with ASME 1/2 in. class 300 connection raised face
2
88;
/T31
/T21+ventilation Insulation, heat tracing and ventilation with ASME 1/2 in. class 150 connection raised face
2
89;
/T32
/T22+ventilation Insulation, heat tracing and ventilation with ASME 1/2 in. class 300 connection raised face
2
90;
25;
25;
029 Fixing device
/PD
2 in. pipe mounting set
91;
26;
26;
034 Connect. cable type + len.
/L000
No std connecting cab No standard connecting cable separate order for standard sensor cable
9
92;
/L005
5m (16,4 ft) std cab 5 meter (16,4 ft) remote sensor cable terminated non Ex black / Ex blue
9
93;
/L010
10m (32,8 ft) std cab 10 meter (32,8 ft) remote sensor cable terminated non Ex black / Ex blue
9
94;
/L015
15m (49,2 ft) std cab 15 meter (49,2 ft) remote sensor cable terminated non Ex black / Ex blue
9
95;
/L020
20m (65,6 ft) std cab 20 meter (65,6 ft) remote sensor cable terminated non Ex black / Ex blue
9
96;
/L030
30m (98,4 ft) std cab 30 meter (98,4 ft) remote sensor cable terminated non Ex black / Ex blue
9
97;
27;
27;
036 Customized install. length
/CL
Customer install. length Customer-specific installation length
98;
/NL
NAMUR install. length NAMUR installation length acc. NE132
99;
28;
28;
040 Steel arm. connect. cable
/LAC
Steel armored cable Steel armored version of standard connecting cable
100;
29;
29;