RCEG2HS Qnom = 500 t/h (18000 lb/min)
01 Process Connection
(Please make one selection)
-1FBA1
6" ASME flange class 150, process connection dimension and facing according ASME B16.5
1
2;
-1FBA2
6" ASME flange class 300, process connection dimension and facing according ASME B16.5
1
3;
-1FBA4
6" ASME flange class 600, process connection dimension and facing according ASME B16.5
1
4;
-1FCA4
6" ASME flange class 600, process connection dimension and facing according ASME B16.5, ring joint
1
5;
-2HBA1
8" ASME flange class 150, process connection dimension and facing according ASME B16.5
1
6;
-2HBA2
8" ASME flange class 300, process connection dimension and facing according ASME B16.5
1
7;
-2HBA4
8" ASME flange class 600, process connection dimension and facing according ASME B16.5
1
8;
-2HCA4
8" ASME flange class 600, process connection dimension and facing according ASME B16.5, ring joint
1
9;
2;
2;
02 Sensor housing material
(Please make one selection)
0
sensor housing material SUS 304 (1.4301)
10;
1
sensor housing material SUS 316L(1.4404)
11;
3;
3;
03 Medium temperature range
(Please make one selection)
-0
standard process fluid temperature range integral: -50 to 150°C (-58 to 302 °F) remote: -70 to 150°C (-56,7 to 302 °F)
12;
-2
mid temperature process fluid temperature range remote: -70 to 230°C (-56,7 to 446 °F)
2
13;
-3
high temperature process fluid temperature range remote: 0 to 350°C (32 to 662 °F)
2,18
14;
4;
4;
04 Mass flow and density accuracy
(Please make one selection)
70
G: 0,75% m flow gas: 0,75% mass flow accuracy
15;
E7
L: 0,2% m flow+4 kg/m³ liquid: 0,2% mass flow accuracy and 4 kg/m³ density accuracy
16;
5;
5;
05 Design and housing
(Please make one selection)
0
I:AL housing UP paint integral: low copper aluminium housing urethane-cured polyester powder coating
3,4
17;
2
I:AL housing corrosion paint integral: low copper aluminium housing corrosion protection coating
3,4
18;
A
R:AL UP+SS std-neck remote: low copper aluminium housing urethane-cured polyester powder coating SS terminal housing standard neck
4,9
19;
B
R:AL UP+SS long-neck remote: low copper aluminium housing urethane-cured polyester powder coating SS terminal housing long neck
10
20;
E
R:AL corr paint+ std-neck remote: low copper aluminium housing corrosion protection coating SS terminal housing standard neck
4,9
21;
F
R:AL corr paint+SS long-neck remote: low copper aluminium housing corrosion protection coating SS terminal housing long neck
22;
J
R:SS trans+SS std-neck remote: stainless steel housing stainless steel terminal housing standard neck
4,9
23;
K
R:SS trans+SS long-neck remote: stainless steel housing stainless steel terminal housing long neck
10
24;
6;
6;
06 Ex approval
(Please make one selection)
-FF11
FM XP tra+IS sen ABCDEFG FM approval for USA and Canada explosionproof transmitter and intrinsic safe sensor (GP ABCDEFG)
25;
-FF12
FM XP tra+IS sen CDEFG FM approval for USA and Canada explosionproof transmitter and intrinsic safe sensor (GP CDEFG)
26;
-NN00
non Ex proof
5
27;
7;
7;
07 Cable entries
-2
ANSI 1/2 in. NPT
28;
8;
8;
08 Communication type and I/O
(Please make one selection)
-JA
IOa, PLp 1 active current output HART, 1 passive pulse output or status output
29;
-JB
IOa, PLp, PLp, IOa 2 active current output HART 2 passive pulse output or status output
30;
-JC
IOa, PLp, DI, IOa 2 active current output HART 1 passive pulse output or status output 1 voltage-free digital input
31;
-JD
IOa, PLp,STp, PLp 1 active current output HART 2 passive pulse output or status output 1 passive status output
32;
-JE
IOa, PLp, DI, PLp 1 active current output HART 2 passive pulse output or status output 1 voltage-free digital input
33;
-JF
IOa, PLp, DI, PLa pull-up 1 active current out HART, 1 passive pulse or statusout,1active pull-up pulse or statusout,1voltage-free digital input
34;
-JG
IOa, PLp, DI, PLa 1 active current out HART, 1 passive pulse or status out, 1 active pulse or status out, 1 voltage-free digital input
35;
-JP
IOp, PLp, IOp 1 passive current output HART, 1 passive pulse output or status output, 1 passive current output,
7
36;
-JQ
IOp, PLp, IOp, PLp 1 passive current output HART, 2 passive pulse output or status output, 1 passive current output
7
37;
-JR
IOp, NamPLp, IOp, 1 passive current output HART, 1 passive Namur pulse or status output, 1 passive current output
7
38;
-JS
IOp, NamPLp, IOp, NamPLp 1 passive current output HART, 2 passive Namur pulse or status output, 1 passive current output
7
39;
-M0
MB, PLp 1 passive pulse output or status output, Modbus
11
40;
-M3
MB, PLp, PLp 2 passive pulse output or status output, Modbus
11
41;
-M4
MB, PLa, PLp 1 active pulse output or status output, 1 passive pulse output or status output, Modbus
11
42;
-M5
MB, PLa pull-up, PLp 1 active pulse ouput or status output with internal pull-up resistor, 1 passive pulse out or status out,Modbus
11
43;
-M6
MB, IOa, PLp 1 active current output, 1 passive pulse output or status output, Modbus
11
44;
9;
9;
09 Display
1
with display
45;
10;
10;
002 Add. namplate information
/BG
Tag number on nameplate Customer-specific tag number on nameplate
46;
11;
11;
003 Pre-setting custom. Param.
/PS
Presetting sel. parameters Presetting of selected parameters based on customer data
14
47;
12;
12;
007 Rupture disc
/RD
rupture disk rupture disk
9
48;
13;
13;
008 Customer-specific calibr.
/K2
5 pt calibr+factory cert Customized 5 point mass-/volume-flow calibration using water with factory certificate
49;
/K5
10 pt calibr+Dakks cert Customized 10 point mass-/volume-flow calibration using water with DAkkS certificate
50;
14;
14;
009 Certificate of Compliance
/P2
2.1 certificate EN 10204 Declaration of compliance with the order 2.1 acc. EN 10204
51;
/P3
3.1 certificate EN 10204 Inspection certificate 3.1 acc. EN 10204 (QIC)
52;
15;
15;
010 material certificates
/P6
material certificate acc. to EN 10204: 2004 -3.1 incl. IGC conform to NACE MR0175, MR0103
53;
16;
16;
012 Pressure testing
/P8
Pressure test certificate Pressure test certificate
54;
17;
17;
013 Surface oil & grease free
/H1
Degreasing wetted surfaces Degreasing of wetted surfaces acc. ASTM G93/G93M-19, level C, test report
55;
18;
18;
014 welding certificate
/WP
incl.: WPS, WPQR, WQC WPS according DIN EN ISO 15609-1 WPQR according DIN EN ISO 15614-1 WQC according DIN EN 287-1 and ISO6906-4
17
56;
/WPA
weld. proced. acc ASME IX Welding procedures and certificate welding according ASME IX
15
57;
19;
19;
015 calibration certificate
/L2
calibration certificate with working standards
58;
/L3
calibration certificate with primary standards
59;
/L4
calibration certificate including measuring instruments control system
60;
20;
20;
016 ASME B31.3 compliance
/P15
ASME B31.3 NORM FLU. SER ASME B31.3 compliance NORMAL FLUID SERVICE
15
61;
21;
21;
017 X-ray insp. flg. weld seam
/RT
X-ray test flange weld X-ray examination of flange welding acc. DIN EN ISO 17636-1/B, AD2000 HP 5/3 DIN EN ISO 5817/C, including certificate
17
62;
/RTA
X-ray test acc. ASME V Dye penetrant test of flange welding acc. ASME V including test report
15
63;
22;
22;
018 PMI of wetted parts
/PM
PMI test PMI test for pressure containing parts, including certificate
64;
23;
23;
019 Dye penetr. test weld seam
/PT
Dye pen test flange weld Dye penetrant test of flange welding acc. DIN EN ISO 3452-1 including test report
17
65;
/PTA
Dye pen. test acc ASME V Dye penetrant test of flange welding acc. ASME V including test report
15
66;
24;
24;
020 combined certificate
/P20
comb /PTA+/WPA+/RTA Dye Penetrant test for flange acc ASME V welding procedure for flange acc ASME IX X-ray test according ASME V
16
67;
/P21
comb /P10+/P20 Quality Inspection Cert.(QIC), cert. of marking transfer, pressure test cert. , ASME cert. Package
68;
/P22
comb /P11+/P20 Quality Insp. Cert.(QIC), cert. of marking transfer, ASME cert. Package, PMI test of pressure containing parts
69;
25;
25;
021 Tube health check
/TC
Tube health check Tube health check
70;
26;
26;
024 Transmitter rotated 180°
/RB
180° rotatable term box 180 degrees rotated terminal box
71;
27;
27;
034 Connect. cable type + len.
/L000
No std connecting cab No standard connecting cable separate order for standard sensor cable
8
72;
/L005
5m (16,4 ft) std cab 5 meter (16,4 ft) remote sensor cable terminated non Ex black / Ex blue
8
73;
/L010
10m (32,8 ft) std cab 10 meter (32,8 ft) remote sensor cable terminated non Ex black / Ex blue
8
74;
/L015
15m (49,2 ft) std cab 15 meter (49,2 ft) remote sensor cable terminated non Ex black / Ex blue
8
75;
/L020
20m (65,6 ft) std cab 20 meter (65,6 ft) remote sensor cable terminated non Ex black / Ex blue
8
76;
/L030
30m (98,4 ft) std cab 30 meter (98,4 ft) remote sensor cable terminated non Ex black / Ex blue
8
77;
28;
28;
040 Steel arm. connect. cable
/LAC
Steel armored cable Steel armored version of standard connecting cable
78;
29;
29;