EJX430A Gauge Pressure Transmitter (GS 01C25E01-01EN)
01 Output Signal
(Please make one selection)
-D
4 to 20 mA DC with digital communicaiton (BRAIN protocol)
2;
-E
4 to 20 mA DC with digital communication (HART protocol)
3;
-J
4 to 20 mA DC with digital communication (HART 5/HART 7 protocol)
4;
-F
Digital communication (FOUNDATION Fieldbus protocol)
5;
-G
Digital communication (PROFIBUS PA protocol)
6;
2;
2;
02 Measurement Span (Capsule)
(Please make one selection)
A
2.5 to 500 psig
7;
B
12 to 2,300 psig
8;
H
10 to 2,000 inH2O
9;
3;
3;
03 Wetted Parts Material
(Please make one selection)
S
Cover flange: ASTM CF-8M, Capsule: Hastelloy C-276(diaphragm), (F)316L SST(others), Vent plug: 316 SST, Process connector: ASTM CF-8M
1
10;
A
Cover flange: Hastelloy C-276 equiv. Capsule: Hastelloy C-276(diaphragm and others) Process connector: Hastelloy C-276 equiv. Vent plug: Hastelloy C-276
11;
B
Cover flange: Monel equivalent Capsule: Monel(diaphragm and others) Process connector: Monel equivalent vent plug: Monel
12;
D
Cover flange: Hastelloy C-276 equiv. Capsule: Tantalum(diaphragm and others) Process connector: Hastelloy C-276 equiv. Vent plug: Hastelloy C-276
13;
H
Cover flange: ASTM CF-8M Capsule: Hatelloy C-276(diaphragm and others) Process connector: ASTM CF-8M Vent plug: 316 SST
14;
L
Cover flange: ASTM CF-3M, Capsule: Hastelloy C-276(diaphragm), (F)316L SST(others), Vent plug: 316L SST Process connector: ASTM CF-3M
15;
M
Cover flange: ASTM CF-8M Capsule: Monel (diaphragm and others) Process connector: ASTM CF-8M Vent plug: 316 SST
16;
T
Cover flange: ASTM CF-8M Diaphragm: Tantalum Vent plug: 316 SST Process connector: ASTM CF-8M
17;
W
Cover flange: Duplex SST equiv. Capsule: Hastelloy C-276(diaphragm and others) Process connector: Duplex SST equiv. Vent plug: Duplex SST
18;
4;
4;
04 Process Connections
(Please make one selection)
3
With 1/4NPT female process connector
19;
4
With 1/2NPT female process connector
20;
5
Without process connector (1/4 NPT female on cover flange)
21;
W
Assembled with low volume cover flange on high pressure side for diaphragm seal unit with M12 x 1.25 female thread, and shipped with two new capsule gaskets
1
22;
0
Without process connector (RC1/4 female on cover flanges)
23;
1
With Rc1/4 female process connector
24;
2
With Rc1/2 female process connector
25;
5;
5;
05 Bolts and Nuts Material
(Please make one selection)
C
ASTM grade660 stainless steel
26;
G
316L SST
27;
J
ASTM-B7 carbon steel
28;
6;
6;
06 Installation
(Please make one selection)
-7
Vertical impulse piping type, left side high pressure, process connectors downside
29;
-9
Horizontal impulse piping type, left side high pressure
1
30;
-3
Vertical impulse piping type, right side high pressure, process connectors downside
31;
-8
Horizontal impulse piping type, right side high pressure
32;
-B
Bottom process connection type, left side high pressure
2
33;
-U
Universal flange
2
34;
7;
7;
07 Amplifier Housing
(Please make one selection)
1
Material:Cast-aluminum alloy
35;
2
Material: ASTM CF-8M
3
36;
3
Material: Cast aluminum alloy with corrosion resistance properties
4
37;
8;
8;
08 Electrical Connection (2 Connectors)
(Please make one selection)
2
1/2 NPT female, two electrical connections without blind plugs
38;
7
1/2 NPT female, two electrical connections with a blind plug
6
39;
C
1/2 NPT female, two electrical connections with a 316 SST blind plug
40;
0
G 1/2 female, one electrical connection without blind plugs
41;
4
M20 female, two electrical connections without blind plugs
42;
5
G1/2 female, two electrical connections with a blind plug
5
43;
9
M20 female, two electrical connections with a blind plug
5
44;
A
G 1/2 female, two electrical connections with a 316 SST blind plug
45;
D
M20 female, two electrical connections with a 316 SST blind plug
46;
9;
9;
09 Integral Indicator
(Please make one selection)
D
Digital indicator
7
47;
E
Digital indicator with a range setting switch
8
48;
N
None
49;
10;
10;
10 Mounting Bracket
(Please make one selection)
B
304 SST 2-inch pipe mounting(flat type)
50;
D
304 SST or SCS13A 2-inch pipe mounting(L type)
51;
J
316 SST 2-inch pipe mounting(flat type)
52;
K
316 SST or SCS14A 2-inch pipe mounting(L type)
53;
M
316 SST or SCS14A 2-inch pipe mounting (for bottom process connection)
9
54;
N
None
55;
P
Position adjustable bracket for vertical piping installation, SUS316, 2-inch pipe mounting(L type)
56;
11;
11;
001 Optional Features
/CF1
CSA Explosionproof Approval
(For Output Code -D, -E, -J, -F, or -G)
10
57;
/CS1
CSA Intrinsically safe Approval
(For Output Code -D, -E, or -J)
11
58;
/CS15
CSA Intrinsically safe approval
(For Output Signal code -F)
11
59;
/CU1
Combined /CF1 and /CS1
(For Output Code -D, -E, or -J)
11
60;
/FF1
FM Explosionproof Approval (For Output Code -D, -E, -J, -F, or -G)
10
61;
/FS1
FM Intrinsically Safe Approval
(For Output Code -D, -E, or -J)
11
62;
/FS15
FM Intrinsically Safe and Non-incendive Approval
(For Output Code -F)
11
63;
/FU1
Combined /FF1 and /FS1
(For Output Code -D, -E, or -J)
11
64;
/KF22
ATEX Flameproof Approval (For Output Code -D, -E, -J, -F, or -G)
10
65;
/KN26
ATEX Type n Approval
(For Output Code -F or -G)
11
66;
/KS21
ATEX Intrinsically safe Approval
(For Output Code -D, -E, or -J)
11
67;
/KS26
ATEX Intrinsically safe Approval
(For Output Code -F or -G)
11
68;
/KU22
Combined /KF22, /KS21, and Type n
(For Output Code -D, -E, or -J)
11
69;
/NF21
NEPSI Flameproof and Dust Ignition Proof approval (Output Signal code -D, -E, or -J)
10
70;
/NS21
NEPSI Intrinsically safe Approval (For Output Signal code -D, -E, or -J)
11
71;
/NS25
NEPSI Intrinsic safety Approval (Output Signal code -F)
11
72;
/PF22
KOSHA Flameproof Approval (For Output Signal code -D or -J)
10
73;
/PS21
KOSHA Intrinsically safe Approval (For Output Signal code -D or -J)
11
74;
/SF22
IECEx flameproof approval
(For Output Signal code -D, -J, -F, -G or -Q)
10
75;
/SS26
IECEx Intrinsically safe Approval (Output Signal code -F and -G)
11
76;
/SU22
IECEx Intrinsically safe and flameproof (For Output Signal code -D or -J)
11
77;
/UF1
INMETRO Flameproof Approval (For Output Signal code -D, -E, or -J)
10
78;
/US1
INMETRO Intrinsically safe Approval (For Output Signal code -D, -E, or -
J)
11
79;
/V1U1
Combination Approval (/KU22, /FU1, and /CU1)
(For Output Signal code -D, -E, or -J)
11
80;
12;
12;
003 Optional Features
/D1
P calibration (psi unit)
21
81;
/D3
bar calibration (bar unit)
21
82;
/D4
M calibration (kgf/cm2 unit)
21
83;
13;
13;
004 Optional Features
/P1
Color change, amplifier cover only Munsell code ; N1.5, black
14
84;
/P2
Color change, amplifier cover only Munsell code ; 7.5BG4/1.5, jade green
14
85;
/P7
Color change, amplifier cover only Metallic silver
14
86;
/PR
Color change, amplifier and terminal covers Munsell code; 7.5 R4/14, Red
87;
14;
14;
005 Optional Features
/X2
High anti-corrosion coating
15
88;
15;
15;
006 Optional Features
/A
Lightning protector
89;
16;
16;
007 Optional Features
/K1
Degrease cleansing treatment
18
90;
/K5
Degrease cleansing and dehydrating treatment
18
91;
/K2
Degrease cleansing treatment and with fluorinated oil filled capsule
18
92;
/K3
Fluorinated oil filled capsule
93;
/K41
Degrease cleansing treatment and implementation certificate
18
94;
/K42
Degrease cleansing treatment with fluorinated oil filled capsule, and implementation certificate
18
95;
/K45
Degrease cleansing and dehydrating treatment, and implementation certificate
18
96;
/K46
Degrease cleansing and dehydrating treatment with fluorinated oil filled capsule, and implementation certificate
18
97;
/K6
Degrease cleansing and dehydrating treatment with fluorinated oil filled capsule
18
98;
17;
17;
008 Optional Features
/U1
Long vent
22
99;
18;
18;
009 Optional Features
/C1
Output status at CPU failure and hardware error is -5%, 3.2 mA or less.
100;
/C2
Output signal limits: 3.8 mA to 20.5 mA Output status at CPU failure and hardware error is -5%, 3.2 mA or less.
101;
/C3
Output signal limits: 3.8 mA to 20.5 mA Output status at CPU failure and hardware error is 110%, 21.6 mA or more.
102;
19;
19;
010 Optional Features
/CA
Data Configuration for HART communication type (Software damping, Descriptor and Message)
25
103;
/CB
Data Configuration for BRAIN communication type (Software damping)
25
104;
/CC
Data Configuration for FOUNFATION Fieldbus communication type (Software damping)
25
105;
/CD
Data configuration for PROFIBUS PA communication type (Software damping)
25
106;
/CJ
Data configuration(for HART): Disabling external zero adjustment, Software damping, Descriptor and Message
25
107;
/CK
Data configuration(for BRAIN): Disables external zero adjustment, Software damping
25
108;
20;
20;
011 Optional Features
/M01
Material certificate:cover flange
26
109;
/M11
Material certificate:cover flange, process connector
26
110;
/MA1
Material certificate: Cover flange, diaphragm, capsule body
111;
/MC1
Material certificate: Cover flange, process connector, diaphragm, capsule body
112;
/MG1
Material certificate for wetted parts including cover flange, bolt and nut for cover flange, diaphragm, capsule body, vent and drain plug, vent screw, capsule gasket
113;
/MH1
Material certificate for wetted parts including cover flange, process connector, bolt and nut for cover flange, bolt for process connector, diaphragm, capsule body, vent and drain plug, vent screw, capsule gasket
114;
21;
21;
012 Optional Features
/T01
Pressure test/leak test certificate Test pressure:3.5 MPa(500 psi)
26
115;
/T11
Pressure test/leak test certificate Test pressure:500 kPa(2000 inH2O)
26
116;
/T12
Pressure test/leak test certificate Test pressure:16 MPa(2300 psi)
26
117;
22;
22;
013 Optional Features
/N1
Right side high pressure. Without drain and vent plugs.
24
118;
/N2
Right side high pressure. IEC61518 pro- cess connection with female threads on cover flange, with blind kidney flange on back. Without drain and vent plug.
24
119;
/N3
Right side high pressure. /N1,/N2 and material certificate for cover flange, diaphragm, capsule body and blind kidney flange.
24
120;
23;
23;
014 Optional Features
/N4
Stainless steel tag plate wired onto the transmitter
27
121;
24;
24;
016 Optional Features
/A1
Gold-plated diaphragm
19
122;
/A2
Gold-plated diaphragm (10 micro meter)
20
123;
25;
25;
017 Optional Features
/AL
Status output
17
124;
26;
26;
019 Optional Features
/HAC
High accuracy type Reference accuracy: +/-0.025% of span (Refer to GS for details.)
13
125;
27;
27;
021 Optional Features
/EE
Software Download
126;
28;
28;
027 Optional Features
/HC
316 SST exterior parts
16
127;
29;
29;
028 Optional Features
/GS
Gold-plated capsule gasket Without drain and vent plugs
23
128;
30;
30;
036 Optional Features
/WCA
American Bureau of Shipping (ABS) Type Approval (For Output Signal
code -D or -J)
12
129;
/WCB
Bureau Veritas Type Approval
12
130;
/WCD
Det Norske Veritas (DNV) Type Approval (For Output Signal code -D or -
J)
12
131;
/WCL
Lloyd's Register of Shipping Type Approval (For Output Signal code -D
or -J)
12
132;
/WCN
NK(Nippon Kaiji Kyokai) Type approval
12
133;
31;
31;
039 Optional Features
/YP
Parameter List
134;
32;
32;
043 Optional Features
/SLT
Low temperature expansion of functional safety ambient temperature
135;
33;
33;
046 Optional Features
/L4
Calibration certificate: Introduction and Yokogawa traceability control system
136;
/L5
Calibration certificate: Introduction, Yokogawa traceability control system, and primary standards list
137;
/L6
Calibration certificate: Introduction, Yokogawa traceability control system, primary standards list, and calibration equipments list
138;
/L9
Calibration certificate: Introduction, Yokogawa traceability control system, primary standards list, calibration equipments list and their test cert.
139;
34;
34;
050 Optional Features
/BS
Bug screen
29
140;
35;
35;
051 Optional Features
/PP
An additional blind plug
28
141;
36;
36;