EJX310A Absolute Pressure Transmitter (GS 01C25D01-01EN)
01 Output Signal
(Please make one selection)
-D
4 to 20 mA DC with digital communication (BRAIN protocol)
2;
-E
4 to 20 mA DC with digital communication (HART protocol)
3;
-F
Digital communication (FOUNDATION Fieldbus protocol)
4;
-G
Digital communication (PROFIBUS PA protocol)
5;
-J
4 to 20 mA DC with digital communication (HART 5/HART 7 protocol)
6;
2;
2;
02 Measurement Span (Capsule)
(Please make one selection)
A
2.5 to 500 psia
7;
B
10 to 2,300 psia
8;
L
0.15 to 2.95 inHg
15
9;
M
0.39 to 38 inHg
10;
3;
3;
03 Wetted Parts Material
(Please make one selection)
S
Cover flange: ASTM CF-8M, Capsule: Hastelloy C-276(diaphragm), (F)316L SST(others), Vent plug: 316 SST, Process connector: ASTM CF-8M
11;
L
Cover flange: ASTM CF-3M, Capsule: Hastelloy C-276(diaphragm), (F)316L SST(others), Vent plug: 316L SST Process connector: ASTM CF-3M
12;
4;
4;
04 Process Connections
(Please make one selection)
5
Without process connector (1/4 NPT female on cover flange)
13;
0
Without process connector (RC 1/4 female on cover flanges)
14;
1
With Rc1/4 female process connector
15;
2
With Rc1/2 female process connector
16;
3
With 1/4NPT female process connector
17;
4
With 1/2NPT female process connector
18;
5;
5;
05 Bolts and Nuts Material
(Please make one selection)
C
ASTM grade660 stainless steel
19;
G
316L SST
20;
J
ASTM-B7 carbon steel
21;
6;
6;
06 Installation
(Please make one selection)
-3
Vertical impulse piping type, right side high pressure, process connectors downside
22;
-7
Vertical impulse piping type, left side high pressure, process connectors downside
23;
-8
Horizontal impulse piping type, right side high pressure
24;
-9
Horizontal impulse piping type, left side high pressure
25;
-B
Bottom process connection type, left side high pressure
26;
-U
Universal flange
27;
7;
7;
07 Amplifier Housing
(Please make one selection)
1
Material: Cast-aluminum alloy
28;
2
Material: ASTM CF-8M
2
29;
3
Material: Cast aluminum alloy with corrosion resistance properties
2
30;
8;
8;
08 Electrical Connection (2 Connectors)
(Please make one selection)
2
1/2 NPT female, two electrical connections without blind plugs
31;
4
M20 female, two electrical connections without blind plugs
32;
7
1/2 NPT female, two electrical connections with a blind plug
16
33;
9
M20 female, two electrical connections with a blind plug
16
34;
C
1/2 NPT female, two electrical connections with a 316 SST blind plug
35;
D
M20 female, two electrical connections with a 316 SST blind plug
36;
9;
9;
09 Integral Indicator
(Please make one selection)
N
None
37;
D
Digital Indicator
19
38;
E
Digital indicator with a range setting switch
1
39;
10;
10;
10 Mounting Bracket
(Please make one selection)
B
304 SST 2-inch pipe mounting(flat type)
40;
D
304 SST or SCS13A 2-inch pipe mounting(L type)
41;
J
316 SST 2-inch pipe mounting(flat type)
42;
K
316 SST or SCS14A 2-inch pipe mounting(L type)
43;
M
316 SST or SCS14A 2-inch pipe mounting (for bottom process connection)
18
44;
N
None
45;
P
Position adjustable bracket for vertical piping installation, SUS316, 2-inch pipe mounting(L type)
46;
11;
11;
001 Optional Features
/CF1
CSA Explosionproof Approval
(For Output Code -D, -E, -J, -F, or -G)
4
47;
/CS1
CSA Intrinsically safe Approval
(For Output Code -D, -E, or -J)
48;
/CS15
CSA Intrinsically safe approval
(For Output Signal code -F)
49;
/CU1
Combined /CF1 and /CS1
(For Output Code -D, -E, or -J)
50;
/FF1
FM Explosionproof Approval (For Output Code -D, -E, -J, -F, or -G)
4
51;
/FS1
FM Intrinsically Safe Approval
(For Output Code -D, -E, or -J)
52;
/FS15
FM Intrinsically Safe and Non-incendive Approval
(For Output Code -F)
53;
/FU1
Combined /FF1 and /FS1
(For Output Code -D, -E, or -J)
54;
/KF22
ATEX Flameproof Approval (For Output Code -D, -E, -J, -F, or -G)
4
55;
/KN26
ATEX Type n Approval
(For Output Code -F or -G)
56;
/KS21
ATEX Intrinsically safe Approval
(For Output Code -D, -E, or -J)
57;
/KS26
ATEX Intrinsically safe Approval
(For Output Code -F or -G)
58;
/KU22
Combined /KF22, /KS21, and Type n
(For Output Code -D, -E, or -J)
59;
/NF21
NEPSI Flameproof and Dust Ignition Proof approval (Output Signal code -D, -E, or -J)
4
60;
/NS21
NEPSI Intrinsically safe Approval (For Output Signal code -D, -E, or -J)
61;
/NS25
NEPSI Intrinsic safety Approval (Output Signal code -F)
62;
/PF22
KOSHA Flameproof Approval (For Output Signal code -D or -J)
4
63;
/PS21
KOSHA Intrinsically safe Approval (For Output Signal code -D or -J)
64;
/SF22
IECEx flameproof approval
(For Output Signal code -D, -J, -F, -G or -Q)
4
65;
/SS26
IECEx Intrinsically safe Approval (Output Signal code -F and -G)
66;
/SU22
IECEx Intrinsically safe and flameproof (For Output Signal code -D or -J)
67;
/UF1
INMETRO Flameproof Approval (For Output Signal code -D, -E, or -J)
4
68;
/US1
INMETRO Intrinsically safe Approval (For Output Signal code -D, -E, or -
J)
69;
/V1U1
Combination Approval (/KU22, /FU1, and /CU1)
(For Output Signal code -D, -E, or -J)
70;
12;
12;
003 Optional Features
/D1
P calibration (psi unit)
17
71;
/D3
bar calibration (bar unit)
17
72;
/D4
M calibration (kgf/cm2 unit)
17
73;
13;
13;
004 Optional Features
/P1
Color change, amplifier cover only Munsell code ; N1.5, black
3
74;
/P2
Color change, amplifier cover only Munsell code ; 7.5BG4/1.5, jade green
3
75;
/P7
Color change, amplifier cover only Metallic silver
3
76;
/PR
Color change, both sides of amplifier cover Munsell code ; 7.5 R4/14, Red
3
77;
14;
14;
005 Optional Features
/X2
High anti-corrosion coating
3
78;
15;
15;
006 Optional Features
/A
Lightning protector
79;
16;
16;
007 Optional Features
/K1
Degrease cleansing treatment
80;
/K2
Degrease cleansing treatment and with fluorinated oil filled capsule
81;
/K3
Fluorinated oil filled capsule
82;
/K41
Degrease cleansing treatment and implementation certificate
21
83;
/K42
Degrease cleansing treatment with fluorinated oil filled capsule, and implementation certificate
21
84;
/K45
Degrease cleansing and dehydrating treatment, and implementation certificate
21
85;
/K46
Degrease cleansing and dehydrating treatment with fluorinated oil filled capsule, and implementation certificate
21
86;
/K5
Degrease cleansing and dehydrating treatment
87;
/K6
Degrease cleansing and dehydrating treatment with fluorinated oil filled capsule
88;
17;
17;
008 Optional Features
/U1
Long vent
5
89;
18;
18;
009 Optional Features
/C1
Output status at CPU failure and hardware error is -5%, 3.2 mA or less.
6
90;
/C2
Output signal limits: 3.8 mA to 20.5 mA Output status at CPU failure and hardware error is -5%, 3.2 mA or less.
6
91;
/C3
Output signal limits: 3.8 mA to 20.5 mA Output status at CPU failure and hardware error is 110%, 21.6 mA or more.
6
92;
19;
19;
010 Optional Features
/CA
Data Configuration for HART communication type (Software damping, Descriptor and Message)
93;
/CB
Data Configuration for BRAIN communication type (Software damping)
94;
/CC
Data Configuration for FOUNFATION Fieldbus communication type (Software damping)
95;
/CD
Data configuration for PROFIBUS PA communication type (Software damping)
96;
/CJ
Data configuration(for HART): Disabling external zero adjustment, Software damping, Descriptor and Message
23
97;
/CK
Data configuration(for BRAIN): Disables external zero adjustment, Software damping
23
98;
20;
20;
011 Optional Features
/M01
Material certificate:cover flange
99;
/M11
Material certificate:cover flange, proce connector
100;
/MA1
Material certificate: Cover flange, diaphragm, capsule body
101;
/MC1
Material certificate: Cover flange, process connector, diaphragm, capsule body
102;
/MG1
Material certificate for wetted parts including cover flange, bolt and nut for cover flange, diaphragm, capsule body, vent and drain plug, vent screw, capsule gasket
103;
/MH1
Material certificate for wetted parts including cover flange, process connector, bolt and nut for cover flange, bolt for process connector, diaphragm, capsule body, vent and drain plug, vent screw, capsule gasket
104;
21;
21;
012 Optional Features
/T01
Pressure test/leak test certificate Test pressure:3.5 MPa(500 psi)
105;
/T04
Pressure test/leak test certificate Test pressure:50 kPa(200 inH2O)
106;
/T12
Pressure test/leak test certificate Test pressure:16 MPa(2300 psi)
107;
22;
22;
013 Optional Features
/N1
Without drain and vent plugs
7
108;
/N2
Right side high pressure. IEC61518 pro- cess connection with female threads on cover flange, with blind kidney flange on back. Without drain and vent plug.
7
109;
/N3
/N1, /N2 and material certificate for cover flange, diaphragm, capsule body and blind kidney flange
7
110;
23;
23;
014 Optional Features
/N4
Stainless steel tag plate wired onto the transmitter
20
111;
24;
24;
015 Optional Features
/S1
130Pa abs(1mmHg abs) calibration
8
112;
25;
25;
016 Optional Features
/A1
Gold-plated diaphragm
113;
/A2
Gold-plated diaphragm (10 micro meter)
14
114;
26;
26;
017 Optional Features
/AL
Status output
1, 4
115;
27;
27;
021 Optional Features
/EE
Software Download
116;
28;
28;
027 Optional Features
/HC
316 SST exterior parts
9
117;
29;
29;
028 Optional Features
/GS
Gold-plated capsule gasket Without drain and vent plugs
13
118;
30;
30;
036 Optional Features
/WCA
American Bureau of Shipping (ABS) Type Approval (For Output Signal
code -D or -J)
119;
/WCB
Bureau Veritas Type Approval
120;
/WCD
Det Norske Veritas (DNV) Type Approval (For Output Signal code -D or -
J)
121;
/WCL
Lloyd's Register of Shipping Type Approval (For Output Signal code -D
or -J)
122;
/WCN
NK(Nippon Kaiji Kyokai) Type approval
123;
31;
31;
039 Optional Features
/YP
Parameter List
124;
32;
32;
046 Optional Features
/L4
Calibration certificate: Introduction and Yokogawa traceability control system
125;
/L5
Calibration certificate: Introduction, Yokogawa traceability control system, and primary standards list
126;
/L6
Calibration certificate: Introduction, Yokogawa traceability control system, primary standards list, and calibration equipments list
127;
/L9
Calibration certificate: Introduction, Yokogawa traceability control system, primary standards list, calibration equipments list and their test cert.
128;
33;
33;
051 Optional Features
/PP
An additional blind plug
22
129;
34;
34;