EJA430E Gauge Pressure Transmitter (GS 01C31E01-01EN)
01 Output Signal
(Please make one selection)
-D
4 to 20 mA DC with digital communicaiton (BRAIN protocol)
2;
-F
Digital communication (FOUNDATION Fieldbus protocol)
3;
-G
Digital communication (PROFIBUS PA protocol)
4;
-J
4 to 20 mA DC with digital communication (HART 5/HART 7 protocol)
5;
-Q
Low power, 1 to 5 V DC with digital communication (HART 7 protocol)
6;
2;
2;
02 Measurement Span (Capsule)
(Please make one selection)
A
0.03 to 3.5 MPa (4.3 to 500 psi) (0.3 to 35 bar)(0.3 to 35 kgf/cm2)
7;
B
0.14 to 16 MPa (20 to 2300 psi) (1.4 to 160 bar)(1.4 to 160 kgf/cm2)
8;
H
5 to 500 kPa (20 to 2000 inH2O) (0.05 to 5 bar)(0.05 to 5 kgf/cm2)
9;
3;
3;
03 Wetted Parts Material
(Please make one selection)
A
Cover flange: Hastelloy C-276 equiv. Capsule: Hastelloy C-276(diaphragm and others) Process connector: Hastelloy C-276 equiv. Vent plug: Hastelloy C-276
10;
B
Cover flange: Monel equivalent Capsule: Monel(diaphragm and others) Process connector: Monel equivalent vent plug: Monel
11;
D
Cover flange: Hastelloy C-276 equiv. Capsule: Tantalum(diaphragm and others) Process connector: Hastelloy C-276 equiv. Vent plug: Hastelloy C-276
12;
H
Cover flange: ASTM CF-8M Capsule: Hatelloy C-276(diaphragm and others) Process connector: ASTM CF-8M Vent plug: 316 SST
13;
L
Cover flange: ASTM CF-3M, Capsule: Hastelloy C-276(diaphragm), (F)316L SST(others), Vent plug: 316L SST Process connector: ASTM CF-3M
14;
M
Cover flange: ASTM CF-8M Capsule: Monel (diaphragm and others) Process connector: ASTM CF-8M Vent plug: 316 SST
15;
S
Cover flange: ASTM CF-8M, Capsule: Hastelloy C-276(diaphragm), (F)316L SST(others), Vent plug: 316 SST, Process connector: ASTM CF-8M
1
16;
T
Cover flange: ASTM CF-8M Diaphragm: Tantalum Vent plug: 316 SST Process connector: ASTM CF-8M
17;
W
Cover flange, process connector: Super Duplex SST equiv. Capsule: Hastelloy C-276(diaphragm and others) Vent plug: Super Duplex SST
18;
4;
4;
04 Process Connections
(Please make one selection)
0
Without process connector (RC1/4 female on cover flanges)
19;
1
With Rc1/4 female process connector
20;
2
With Rc1/2 female process connector
21;
3
With 1/4NPT female process connector
22;
4
With 1/2NPT female process connector
23;
5
Without process connector (1/4 NPT female on cover flange)
24;
W
Assembled with low volume cover flange on high pressure side for diaphragm seal unit with M12 x 1.25 female thread, and shipped with two new capsule gaskets
1
25;
5;
5;
05 Bolts and Nuts Material
(Please make one selection)
C
ASTM grade660 stainless steel
26;
G
316L SST
27;
J
ASTM-B7 carbon steel
28;
6;
6;
06 Installation
(Please make one selection)
-3
Vertical impulse piping type, right side high pressure, process connectors downside
29;
-7
Vertical impulse piping type, left side high pressure, process connectors downside
30;
-8
Horizontal impulse piping type, right side high pressure
31;
-9
Horizontal impulse piping type, left side high pressure
1
32;
-B
Bottom process connection type, left side high pressure
33;
-U
Universal flange
2
34;
7;
7;
07 Amplifier Housing
(Please make one selection)
1
Material:Cast-aluminum alloy
35;
2
Material: ASTM CF-8M
4
36;
3
Material: Cast aluminum alloy with corrosion resistance properties
3
37;
8;
8;
08 Electrical Connection
(Please make one selection)
0
G 1/2 female, one electrical connection without blind plugs
38;
2
1/2 NPT female, two electrical connections without blind plugs
39;
4
M20 female, two electrical connections without blind plugs
40;
5
G1/2 female, two electrical connections with a blind plug
5
41;
7
1/2 NPT female, two electrical connections with a blind plug
5
42;
9
M20 female, two electrical connections with a blind plug
5
43;
A
G 1/2 female, two electrical connections with a 316 SST blind plug
44;
C
1/2 NPT female, two electrical connections with a 316 SST blind plug
45;
D
M20 female, two electrical connections with a 316 SST blind plug
46;
9;
9;
09 Integral Indicator
(Please make one selection)
D
Digital indicator
6
47;
E
Digital indicator with a range setting switch
7
48;
N
None
49;
10;
10;
10 Mounting Bracket
(Please make one selection)
B
304 SST 2-inch pipe mounting(flat type)
50;
D
304 SST or SCS13A 2-inch pipe mounting(L type)
51;
J
316 SST 2-inch pipe mounting(flat type)
52;
K
316 SST or SCS14A 2-inch pipe mounting(L type)
53;
M
316 SST or SCS14A 2-inch pipe mounting (for bottom process connection)
54;
N
None
55;
P
Position adjustable bracket for vertical piping installation, SUS316, 2-inch pipe mounting(L type)
56;
11;
11;
001 Optional Features
/CF1
CSA Explosionproof Approval
(For Output Signal code -D, -J, -F, -G or -Q)
8
57;
/CS1
CSA Intrinsically Safe Approval
(For Output Signal code -D or -J)
8,16
58;
/CS15
CSA Intrinsically Safe Approval
(For Output Signal Code -F)
8,16
59;
/CU1
Combined /CF1 and /CS1
(For Output Signal code -D or -J)
8,16
60;
/FF1
FM Explosion proof Approval
(For Output Signal code -D,-J,-F, -G or -Q)
8
61;
/FS1
FM Intrinsically Safe Approval
(For Output Signal code -D or -J)
8,16
62;
/FS15
FM Intrinsically Safe and Nonincendive Approval
(For Output Signal code -F)
8,16
63;
/FU1
Combined /FF1 and /FS1
(For Output Signal code -D or -J)
8,16
64;
/KF22
ATEX Flameproof Approval
(For Output Signal code -D, -J, -F, or -G)
8
65;
/KN26
ATEX Intrinsically Safe Approval (Ex ic)
(For Output Signal Code -F or -G)
8,16
66;
/KS21
ATEX Intrinsically Safe Approval
(For Output Signal code -D or -J)
8,16
67;
/KS26
ATEX Intrinsically Safe Approval
(For Output Signal Code -F or -G)
8,16
68;
/KU22
Combined /KF22, /KS21, and Ex ic
(For Output Signal code -D or -J)
8,16
69;
/NF21
NEPSI Flameproof Approval (For Output Signal code -D or -J)
8,16
70;
/NS21
NEPSI Intrinsically safe Approval (For Output Signal code -D or -J)
8,16
71;
/NS25
NEPSI Intrinsic Safety Approval (For Output Signal code -F or -G)
8,16
72;
/PF22
KOSHA Flameproof Approval (For Output Signal code -D or -J)
8,16
73;
/PS21
KOSHA Intrinsically safe Approval (For Output Signal code -D or -J)
8,16
74;
/SF22
IECEx flameproof approval
(For Output Signal code -D, -J, -F, -G or -Q)
8
75;
/SS26
IECEx Intrinsically safe Approval (For Output Signal code -F or -G)
8,16
76;
/SU22
IECEx Intrinsically safe and flameproof (For Output Signal code -D or -J)
8,16
77;
/UF1
INMETRO Flameproof Approval For Output Signal code -D or -J)
8,16
78;
/US1
INMETRO Intrinsically safe Approval (For Output Signal code -D or -J)
8,16
79;
12;
12;
003 Optional Features
/D1
P calibration (psi unit)
80;
/D3
bar calibration (bar unit)
81;
/D4
M calibration (kgf/cm2 unit)
82;
13;
13;
004 Optional Features
/P1
Color change, amplifier cover only Munsell code; N1.5, black
9
83;
/P2
Color change, amplifier cover only Munsell code; 7.5BG4/1.5, jade green
9
84;
/P7
Color change, amplifier cover only Metallic silver
9
85;
/PR
Color change, amplifier and terminal covers Munsell code; 7.5 R4/14, Red
86;
14;
14;
005 Optional Features
/X2
High anti-corrosion coating
18
87;
15;
15;
006 Optional Features
/A
Lightning protector
88;
16;
16;
007 Optional Features
/K1
Degrease cleansing treatment
11
89;
/K2
Degrease cleansing treatment and with fluorinated oil filled capsule
11
90;
/K3
Fluorinated oil filled capsule
91;
/K41
Degrease cleansing treatment and implementation certificate
11
92;
/K42
Degrease cleansing treatment with fluorinated oil filled capsule, and implementation certificate
11
93;
/K45
Degrease cleansing and dehydrating treatment, and implementation certificate
11
94;
/K46
Degrease cleansing and dehydrating treatment with fluorinated oil filled capsule, and implementation certificate
11
95;
/K5
Degrease cleansing and dehydrating
11
96;
/K6
Degrease cleansing and dehydrating treatment with fluorinated oil filled capsule
11
97;
17;
17;
008 Optional Features
/U1
Long vent
12
98;
18;
18;
009 Optional Features
/C1
Failure alarm down-scale
14
99;
/C2
NAMUR NE43 Compliant Output signal limits; Failure alarm down-scale
14
100;
/C3
NAMUR NE43 Compliant Output signal limits; Failure alarm up-scale
14
101;
19;
19;
010 Optional Features
/CA
Data Configuration for HART communication type (Software damping, Descriptor and Message)
102;
/CB
Data Configuration for BRAIN communication type (Software damping)
103;
/CC
Data Configuration for FOUNFATION Fieldbus communication type (Software damping)
104;
/CD
Data configuration for PROFIBUS PA communication type (Software damping)
105;
/CJ
Data configuration(for HART): Disabling external zero adjustment, Software damping, Descriptor and Message
22
106;
/CK
Data configuration(for BRAIN): Disables external zero adjustment, Software damping
22
107;
20;
20;
011 Optional Features
/M01
Material certificate:cover flange
19
108;
/M11
Material certificate:cover flange, process connector
19
109;
/MA1
Material certificate: Cover flange, diaphragm, capsule body
110;
/MC1
Material certificate: Cover flange, process connector, diaphragm, capsule body
111;
/MG1
Material certificate for wetted parts including cover flange, bolt and nut for cover flange, diaphragm, capsule body, vent and drain plug, vent screw, capsule gasket
112;
/MH1
Material certificate for wetted parts including cover flange, process connector, bolt and nut for cover flange, bolt for process connector, diaphragm, capsule body, vent and drain plug, vent screw, capsule gasket
113;
21;
21;
012 Optional Features
/T01
Pressure test/leak test certificate Test pressure:3.5 MPa(500 psi)
19
114;
/T11
Pressure test/leak test certificate Test pressure:500 kPa(2000 inH2O)
19
115;
/T12
Pressure test/leak test certificate Test pressure:16 MPa(2300 psi)
19
116;
22;
22;
013 Optional Features
/N1
Right side high pressure. Without drain and vent plugs.
15
117;
/N2
Right side high pressure. IEC61518 pro- cess connection with female threads on cover flange, with blind kidney flange on back. Without drain and vent plug.
15
118;
/N3
Right side high pressure. /N1,/N2 and material certificate for cover flange, diaphragm, capsule body and blind kidney flange.
15
119;
23;
23;
014 Optional Features
/N4
Stainless steel tag plate wired onto the transmitter
21
120;
24;
24;
016 Optional Features
/A1
Gold-plated diaphragm
2
121;
/A2
Gold-plated diaphragm (10 micro meter)
20
122;
25;
25;
019 Optional Features
/HAC
High accuracy type
2
123;
26;
26;
021 Optional Features
/EE
Software Download function
11
124;
27;
27;
027 Optional Features
/HC
316 SST exterior parts
10
125;
28;
28;
028 Optional Features
/GS
Gold-plated capsule gasket Without drain and vent plugs
13
126;
29;
29;
036 Optional Features
/WCA
American Bureau of Shipping (ABS) Type Approval (For Output Signal
code -D or -J)
127;
/WCB
Bureau Veritas Type Approval (For Output Signal code -D or -J)
128;
/WCD
Det Norske Veritas (DNV) Type Approval (For Output Signal code -D or -
J)
129;
/WCL
Lloyd's Register of Shipping Type Approval (For Output Signal code -D
or -J)
130;
/WCN
Nippon Kaiji Kyokai (NK) Type Approval (For Output Signal code -D or -J)
131;
30;
30;
039 Optional Features
/YP
Parameter List
132;
31;
31;
043 Optional Features
/SLT
Low temperature expansion of functional safety ambient temperature
133;
32;
32;
046 Optional Features
/L4
Calibration certificate: Introduction and Yokogawa traceability control system
134;
/L5
Calibration certificate: Introduction, Yokogawa traceability control system, and primary standards list
135;
/L6
Calibration certificate: Introduction, Yokogawa traceability control system, primary standards list, and calibration equipments list
136;
/L9
Calibration certificate: Introduction, Yokogawa traceability control system, primary standards list, calibration equipments list and their test cert.
137;
33;
33;
050 Optional Features
/BS
Bug screen
24
138;
34;
34;
051 Optional Features
/PP
An additional blind plug
23
139;
35;
35;