Price pages are for price reference only, Refer the General Specification for correct model code configurations and descriptions. Specify the Model Number.
How to build MS Code
Choosing one code from each section. Multiple codes can be chosen form the "Options Section".
Example MS Code
AXG080-GA000BA1AL212B-1JB11/PM/MC/SCT/GRL/M01/L2
Pricing
Total the base price and add the price adders to arrive at a list price.
Delivery
Consult published standard lead times. The quantity ordered as well as any options may affect delivery. Please consult the factory for a more accurate delivery date.
Product Notes
Note Id
Description
1
Please consult Factory for lead times. Some options are delivered from Japan ONLY.
2
Includes calibration certificate and flowtest traceable report. Meters manufactured and tested at YCA are traceable to NIST. Meters manufactured and tested in Japan or China are traceable to the National Institute of Advanced Industrial Science and Technology (AIST).
3
Choose only with integral meter.
4
Choose only with Remote meter.
5
Only for 0.1 to 8 in. (2.5 to 200 mm)
6
Not available for 1.25, 2.5, and 5 in. (32, 65, and 125 mm).
7
Not available for 0.1, 0.2 and 0.4 in. (2.5, 5 and 10 mm).
8
Change the length of signal cable and excitation cable pre-wired with optional code DHC. The maximum cable length is 100 m in combination with the AXG4A transmitter, and 200 m in combination with the AXFA11 transmitter. When optional code L### is not selected, a 30-meter length signal cable and excitation cable are pre-wired.
9
Mandatory combination selection for Grounding rings.
10
Only for 0.1 to 8 in. (2.5 to 200 mm). The mounting bolts, nuts and gaskets of wafer type (process connection code AA1).
11
Please check the table of Applicable Condition for Grounding Devices and Gaskets at General Specification.
12
Mandatory for FM approval type FT2, FJ2, CT2 and CJ2.
13
Only for I/O type #P/#Q/#R/#S/#T.
14
Only for I/O type F0 or G0.
15
Consult Factory if end-user is using with DeltaV
16
Only for Display code: 3 or N.
17
Only for Use -G (General-purpose). Only for Construction A, G (Integral, AXG4A). Only for Communication and I/O J#, M# (HART, Modbus). AX01C maximum cable length up to 15feet due to restrictions on the certification range.
18
Can not be combined with Communication and I/O M#, F0, G0, P0. Can not be combined with DC Noise Cut Circuit ELC.
19
Optional code NSF can be selected with the followings: ・Size: 2.5 to 200 mm (0.1 to 8 in.) ・Lining: A (PFA Lining) ・Electrode: L (Stainless Steel 316L) ・Process Connection: AA1 (ASME Class 150 Wafer) AA2 (ASME Class 300 Wafer) BA1 (ASME Class 150 Flange: Stainless Steel F304) BA2 (ASME Class 300 Flange: Stainless Steel F304) CA1 (ASME Class 150 Flange: Carbon Steel) CA2 (ASME Class 300 Flange: Carbon Steel) ・Grounding Device: 1 (None) 2 (Grounding Rings) + GRL (Stainless Steel 316L, Thin Type) 2 (Grounding Rings) + GRN (Stainless Steel 316L, Thick Type) Not applicable with the following specifi cations: ・Optional Code : Gasket GA, GC, GD, GF and GH
Add Item to Quote
Please select atleast one item to proceed.
Configuration Error
Selected configuration is not valid. Please read notes and make corrections.
Email Verification Required
Email Verification link has been sent successfully.
Please follow instruction in email to verify